PUBLIC HEALTHCARE

Healthcare clean-air systems
for critical clinical environments.

Integrated air treatment, humidity control, cooling and intelligent monitoring for operating rooms, ICU and CCU, CSSD, isolation wards, laboratories and general clinical spaces.

HEALTHCARE CLEAN AIR SYSTEM SOLUTIONS

Controlled air for patient
safety and clinical continuity.

Hospitals place precise demands on air cleanliness, temperature, humidity, airflow organization, fresh-air rates and room pressure relationships. Each clinical area has a different control objective, while every system must support infection control, continuous operation, energy efficiency and maintainability.

Airmaster coordinates air-handling units, chilled and hot water sources, terminal hcEquipment and intelligent hcControls to build application-led systems for operating suites, intensive care, sterile supply, isolation and laboratory environments.

Faq Healthcare Scene

CLEAN
AIR
HEALTHIER
PEOPLE

——

TYPICAL APPLICATIONS

One system strategy.
Different clinical priorities.

Configure cleanliness, temperature, humidity, airflow and pressure around the needs of each clinical area.

Discuss Your Project

Operating rooms

Stable temperature and humidity, positive pressure and controlled supply airflow.

ICU / CCU

Enhanced filtration, reliable fresh air and stable round-the-clock operation.

CSSD

Humidity control, supply and exhaust coordination, and pressure zoning.

Isolation wards

Negative pressure, contamination containment and coordinated exhaust air.

Clean and PCR laboratories

Temperature, humidity, cleanliness, pressure gradients and biosafety.

General clinical spaces

Comfort, fresh-air quality, noise control, energy use and maintainability.

CUSTOMER & SCENARIO PAIN POINTS

Clinical requirements that must work together.

01

Infection control

Airflow and filtration directly affect airborne and microbial contamination risk.

02

Different room objectives

Operating rooms, ICU, CSSD, laboratories and wards require different cleanliness and pressure relationships.

03

Coordinated humidity and cleanliness

Fresh air, multi-stage filtration and changing occupancy all influence stable temperature and humidity.

04

Pressure relationships

Positive and negative pressure gradients must remain stable across adjacent areas.

05

Continuous reliability

Critical clinical spaces need stable operation, accessible maintenance and clear fault reporting.

06

Energy under high standards

Fresh air and year-round temperature and humidity control require efficient system design.

ENVIRONMENTAL CONTROL REQUIREMENTS

Nine conditions managed
as one coordinated system.

Clinical environments depend on coordinated cleanliness, temperature, humidity, pressure, fresh air, air distribution, microbial control, reliability and intelligent monitoring.

Healthcare Air Cleanliness V2

01. Air cleanliness

Match filtration levels and cleanliness targets to each medical function.

01

Healthcare Temperature Humidity V2

02. Temperature and humidity

Maintain stable temperature and humidity through coordinated cooling, reheating and humidification.

02

Healthcare Pressure Airflow V2

03. Pressure and airflow

Coordinate pressure relationships, fresh-air volume, air change and supply, return and exhaust paths.

03

Healthcare Intelligent Monitoring V2

04. Reliable intelligent control

Combine microbial control, system reliability and central monitoring of environmental and equipment status.

04

A coordinated system from air source to room.

Combine hygienic air handling, heating and cooling sources, terminal equipment, airflow zoning and intelligent controls around the needs of each clinical environment.

Clean-air
handling

AAHM-N and AAHM-H units combine filtration, cooling, heating, humidity treatment, fresh air and pressure control.

Heating and cooling
source

Air-cooled heat pumps and screw chillers provide chilled and hot water for year-round clinical loads.

Terminal
systems

Fan-coil and cabinet units serve offices and auxiliary areas without weakening clinical zoning.

Supply, return
and exhaust

Dedicated air paths maintain positive or negative pressure and contain contamination.

Intelligent
control

Central monitoring coordinates environmental values, alarms, filters and equipment operation.

SYSTEM CONFIGURATION BY AREA

A repeatable framework for healthcare projects.

AREA / PROCESS RECOMMENDED SYSTEM APPROACH CORE CONTROL OBJECTIVE
Operating rooms AAHM-H hygienic AHU + chiller or heat pump + intelligent hcControls Cleanliness, temperature, humidity, positive pressure and operating status
ICU / CCU AAHM-N or AAHM-H AHU + chiller or heat pump + terminals Filtration, fresh air, comfort and stable room pressure
CSSD AAHM-N modular AHU + fresh air and exhaust + hcControls Humidity, exhaust coordination and pressure gradients
Isolation wards Dedicated AHU + exhaust + pressure monitoring Negative pressure and contamination containment
Clean / PCR laboratories AAHM-N or DX AHU + intelligent hcControls Temperature, humidity, cleanliness and pressure gradients
General clinical spaces AFCU or cabinet fan coil + central water system Comfort, fresh-air quality, noise and energy performance

RECOMMENDED EQUIPMENT

Equipment families referenced in the solution document.

Healthcare Aahm H Double Standardized V2

AAHM-H Hygienic AHU

Hygienic air treatment for operating rooms and other critical clean spaces.

Healthcare Aahm H Standardized V2

AAHM-N Modular AHU

Configurable air treatment for ICU, CSSD, laboratories and clinical areas.

Healthcare Air Cooled Heat Pump Standardized V2

Air-Cooled Heat Pump

Chilled and hot water for year-round hospital operation.

Healthcare Air Cooled Screw Standardized V2

Air-Cooled Screw Chiller

Central capacity for larger medical campuses and high-load projects.

Healthcare Terminal Units Standardized V2

Terminal Units

Fan-coil and cabinet units for offices and auxiliary zones.

Healthcare Dx Ahu 1 Standardized V2

Direct Expansion AHU

Integrated cooling and air treatment for project-specific clinical spaces.

Healthcare Dx Ahu 2 Standardized V2

DX Air-Handling Unit

Compact packaged control for laboratories and support areas.

Healthcare Intelligent Control Standardized V2

Intelligent Control System

Central monitoring of environmental values, hcEquipment and alarms.

FROM REQUIREMENT TO OPERATION

Coordinate the clinical environment before selecting hcEquipment.

01

Define room criteria

Confirm room function, cleanliness, temperature, humidity, fresh air and pressure targets.

02

Map pressure zones

Coordinate clean and contaminated routes, supply, return and exhaust air.

03

Configure hcEquipment

Select air-handling, cooling, heating, terminals and control functions around the load.

04

Verify and hand over

Commission airflow, pressure, hcControls, alarms and operating records.

05

Maintain performance

Plan filter replacement, cleaning, inspections and service access.

RELATED HEALTHCARE PROJECTS

Project experience connected to this solution.

These healthcare references use the same solution logic: hygienic air handling, reliable heating and cooling, terminal coordination and intelligent environmental control.

P13 12

Healthcare

Peking Union Medical College Hospital

Beijing, China

Modular heat pumps and hygienic air handling for a major clinical environment.

View Project →
P13 14

Healthcare

West China Hospital, Sichuan University

Chengdu, China

Hygienic air handling and intelligent controls for demanding healthcare spaces.

View Project →
P13 20

Healthcare

Xiangya Hospital, Central South University

Changsha, China

Hygienic air handling, heat pumps and cabinet units coordinated across the project.

View Project →